{"id":1413,"date":"2018-04-09T03:13:15","date_gmt":"2018-04-09T03:13:15","guid":{"rendered":"http:\/\/sw-themes.com\/porto_dummy\/product\/import-placeholder-for-1328\/"},"modified":"2022-04-05T20:14:05","modified_gmt":"2022-04-05T20:14:05","slug":"brine-acid-mag-flow-meter","status":"publish","type":"product","link":"https:\/\/hindelectrical.com\/index.php\/product\/brine-acid-mag-flow-meter\/","title":{"rendered":"Brine Acid MAG Flow Meter"},"content":{"rendered":"<p><strong>Technical Data<\/strong><\/p>\n<table border=\"1\" width=\"712\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td><strong>\u00a0Production Name<\/strong><\/td>\n<td>ILUX-EM-05- Electromagnetic Water Flow Meter Smart<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Medium<\/strong><\/td>\n<td>\u00a0<strong>water; waste water; Mud and various \u00a0kinds of conductivity liquid<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Diameter<\/strong><\/td>\n<td>\u00a0DN10~DN2000mm<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Accuracy<\/strong><\/td>\n<td>\u00a0+\/-0.5%<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Temperature<\/strong><\/td>\n<td>\u00a0&lt;80\u2103(rubber); &lt;180\u2103(PTFE)<\/td>\n<\/tr>\n<tr>\n<td><strong>Pressure<\/strong><\/td>\n<td>\u00a010 kg\/cm&amp;sup2; Max (Higher on Request)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Flow speed<\/strong><\/td>\n<td>\u00a00.3~10m\/s<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Requirement of\u00a0 \u00a0pipeline<\/strong><\/td>\n<td>\u00a0Upstream\u00a0\u22655DN;Downstream\u226410DN<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Electrode<\/strong><\/td>\n<td>\u00a0Stainless steel 316L(standard); Titanium; Tantalum ; Hast alloy<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Lining<\/strong><\/td>\n<td>\u00a0PTFE; \u00a0Rubber<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Connection<\/strong><\/td>\n<td>\u00a0Flange; thread; clamp on<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Body material<\/strong><\/td>\n<td>\u00a0Cast steel ;stainless steel<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Power supply<\/strong><\/td>\n<td>\u00a0220V;24V;Battery<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Output<\/strong><\/td>\n<td>\u00a0Pulse;4~20mA;HART;RS485;MODBUS;GPRS<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Communication<\/strong><\/td>\n<td>\u00a0HART;RS485;MODBUS<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Explosion proof<\/strong><\/td>\n<td>\u00a0Customized<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Protection<\/strong><\/td>\n<td>\u00a0IP65 or IP67<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Environment<\/strong><\/td>\n<td>\u00a0Environment:-20~60\u2103<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table border=\"1\" width=\"730\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<p align=\"center\"><strong>ITEM<\/strong><\/p>\n<\/td>\n<td>\n<p align=\"center\"><strong>ELECTRODE SPECIFICATION<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Material<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0The Medium<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0SS316L<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Water; Waste water; Corrosive water and Mud, etc;<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Hastelloy B<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Non-oxidizing acids at concentrations less than 10%; NAOH Concentrations less than 50%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Hastelloy C<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0Mixed Acid and Oxidizing salts<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Titanium<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Salt and weak acid ;Not application: hydrochloric acid, nitric acid and other reducing acids<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Tantalum<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Hydrochloric acid(&lt;40%); Sulphuric acid and\u00a0Other oxidizing acids<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Platinum<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Almost all acid-base salt solution\u00a0But not application for\u00a0aqua regia, except ammonium salt<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>Tungsten carbide<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Pulp ; sewage ;slurry<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p align=\"center\">\n<p><strong>FLOW METER LINNING SPECIFICATION<\/strong><\/p>\n<table border=\"1\" width=\"728\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td><strong>Lining<\/strong><\/td>\n<td><strong>Name<\/strong><\/td>\n<td><strong>Symbol<\/strong><\/td>\n<td><strong>Performance<\/strong><\/td>\n<td><strong>Temp<\/strong><\/td>\n<td><strong>Medium<\/strong><\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Rubber<\/td>\n<td>Neoprene<\/td>\n<td>CR<\/td>\n<td>Normal wear resistance acid salt<\/td>\n<td>&lt;80c<\/td>\n<td>Water<\/td>\n<td>&nbsp;<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td>Polyurethane<\/td>\n<td>PU<\/td>\n<td>Good wear resistance , bad corrosive resistance<\/td>\n<td>&lt;80c<\/td>\n<td>Pulp<\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Fluoroplastic<\/td>\n<td>Teflon<\/td>\n<td>PTFE<\/td>\n<td>Acid Salt with stable Chemical properties<\/td>\n<td>&nbsp;<\/p>\n<p>&lt;140c<\/td>\n<td>Acid Salt<\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td>Polyvinyl Fluoride<\/td>\n<td>FEP<\/td>\n<td>Chemical\u00a0 properties same<\/td>\n<td>&lt;180c<\/td>\n<td>Acid Salt<\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Flow Meter Installation<\/strong><\/p>\n<p><strong>\u00a01. Installation location<\/strong><\/p>\n<ul>\n<li>Avoid the magnetic objects and equipment with strong electromagnetic field;<\/li>\n<li>should install the flow meter at ventilated location;<\/li>\n<li>Avoid the location wherer ambient temperature above 50\u2103 and relative humidity above 90%;<\/li>\n<li>The water flow meter should be installed at somewhere spacious;<\/li>\n<li>The 4-20Ma Sensor Electromagnetic Water Flow Meter Smart should be installed behind pump and the value should install at downstream.<\/li>\n<\/ul>\n<p><strong>\u00a0 \u00a0 \u00a0 Flow Sensor Installation<\/strong><\/p>\n<ul>\n<li>Must to ensure the pipeline is filled and without bubbles to keep the high accuracy;<\/li>\n<li>The flow direction should keep with sign on the body of flow meter;<\/li>\n<li>Ensure the double electrodes keep Horizontal;<\/li>\n<li>If the medium is mixed by liquid and solid,Pls install it at vertical to extend the working life of lining;<\/li>\n<li>If the environment with shocked pls install the bracket at both front and behind;<\/li>\n<li>If the medium is pollution liquid, should install the flow meter at bypass pipe and don&#8217;t interrupted when you on service;<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p><strong>MODEL NO- ILUX \u2013EM -05 \u00a0\u00a0BRINE ACID MAG FLOW METER<\/strong><\/p>\n<p><strong>Principle of Operation<\/strong><\/p>\n<p>Faraday&#8217;s Law The operation of a magnetic flow meter or mag meter<\/p>\n<p>is based upon Faraday&#8217;s Law, which states that the voltage induced<\/p>\n<p>across any conductor as it moves at right angles through a magnetic<\/p>\n<p>field is proportional to the velocity of that conductor.<\/p>\n<p><strong>Faraday&#8217;s Formula<\/strong><\/p>\n<p>E is proportional to V x B x D where:<\/p>\n<p>E = The voltage generated in a conductor<\/p>\n<p>V = The velocity of the conductor<\/p>\n<p>B = The magnetic field strength<\/p>\n<p>D = The length of the conductor<\/p>\n<p><strong>Application :<\/strong><\/p>\n<p><strong>Brine Acid Flow Meter Flowmeter with pulse;4~20mA and RS485 output optional<\/strong><\/p>\n<p><strong>Sensor Output:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong><\/p>\n<p>Pulse;4~20mA;HART;RS485;MODBUS;GPRS<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Lining and Body\u00a0 Matereial<\/strong><\/p>\n<p>PTFE, Rubber Lining and cast<\/p>\n<p>steel; stainless steel body material<\/p>\n","protected":false},"featured_media":3206,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[121,64],"product_tag":[],"class_list":["post-1413","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-electromag-flow-meter","product_cat-flow-meter"],"_links":{"self":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product\/1413","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/comments?post=1413"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/media\/3206"}],"wp:attachment":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/media?parent=1413"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1413"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1413"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}