{"id":1385,"date":"2018-04-10T03:11:32","date_gmt":"2018-04-10T03:11:32","guid":{"rendered":"http:\/\/sw-themes.com\/porto_dummy\/product\/import-placeholder-for-1285\/"},"modified":"2022-04-05T18:41:44","modified_gmt":"2022-04-05T18:41:44","slug":"juice-milk-mag-flow-meter","status":"publish","type":"product","link":"https:\/\/hindelectrical.com\/index.php\/product\/juice-milk-mag-flow-meter\/","title":{"rendered":"Juice Milk MAG Flow Meter"},"content":{"rendered":"<h3><strong>Technical Data<\/strong><\/h3>\n<table border=\"1\" width=\"724\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td><strong>\u00a0Production Name<\/strong><\/td>\n<td><strong>MODEL NO- ILUX \u2013EM -03\u00a0 JUICE MILK MAG FLOW METER<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Medium<\/strong><\/td>\n<td>\u00a0<strong>Fruit Juice, Milk, Water; Waste water; Mud and various \u00a0kinds of conductivity liquid<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Diameter<\/strong><\/td>\n<td>\u00a0DN10~DN2000mm<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Accuracy<\/strong><\/td>\n<td>\u00a0+\/-0.5%<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Temperature<\/strong><\/td>\n<td>\u00a0&lt;80\u2103(rubber); &lt;180\u2103(PTFE)<\/td>\n<\/tr>\n<tr>\n<td><strong>Pressure<\/strong><\/td>\n<td>\u00a0\u00a010 kg\/cm&amp;sup2; Max (Higher on Request)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Flow speed<\/strong><\/td>\n<td>\u00a00.3~10m\/s<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Requirement of\u00a0 \u00a0pipeline<\/strong><\/td>\n<td>\u00a0Upstream\u00a0\u22655DN;Downstream\u226410DN<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Electrode<\/strong><\/td>\n<td>\u00a0Stainless steel 316L(standard); Titanium; Tantalum ; Hast alloy<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Lining<\/strong><\/td>\n<td>\u00a0PTFE; \u00a0Rubber<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Connection<\/strong><\/td>\n<td>\u00a0Flange; thread; clamp on<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Body material<\/strong><\/td>\n<td>\u00a0Cast steel ;stainless steel<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Power supply<\/strong><\/td>\n<td>\u00a0220V;24V;Battery<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Output<\/strong><\/td>\n<td>\u00a0Pulse;4~20mA;HART;RS485;MODBUS;GPRS<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Communication<\/strong><\/td>\n<td>\u00a0HART;RS485;MODBUS<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Explosion proof<\/strong><\/td>\n<td>\u00a0Customized<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Protection<\/strong><\/td>\n<td>\u00a0IP65 or IP67<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Environment<\/strong><\/td>\n<td>\u00a0Environment:-20~60\u2103<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table border=\"1\" width=\"730\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<p align=\"center\"><strong>ITEM<\/strong><\/p>\n<\/td>\n<td>\n<p align=\"center\"><strong>ELECTRODE SPECIFICATION<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Material<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0The Medium<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0SS316L<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Water; Waste water; Corrosive water and Mud, etc;<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Hastelloy B<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Non-oxidizing acids at concentrations less than 10%; NAOH Concentrations less than 50%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Hastelloy C<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0Mixed Acid and Oxidizing salts<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Titanium<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Salt and weak acid ;Not application: hydrochloric acid, nitric acid and other reducing acids<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Tantalum<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Hydrochloric acid(&lt;40%); Sulphuric acid and\u00a0Other oxidizing acids<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>\u00a0Platinum<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Almost all acid-base salt solution\u00a0But not application for\u00a0aqua regia, except ammonium salt<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong>Tungsten carbide<\/strong><\/p>\n<\/td>\n<td><strong>\u00a0 Pulp ; sewage ;slurry<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>FLOW METER LINNING SPECIFICATION<\/strong><\/h3>\n<table border=\"1\" width=\"728\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td><strong>Lining<\/strong><\/td>\n<td><strong>Name<\/strong><\/td>\n<td><strong>Symbol<\/strong><\/td>\n<td><strong>Performance<\/strong><\/td>\n<td><strong>Temp<\/strong><\/td>\n<td><strong>Medium<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Rubber<\/td>\n<td>Neoprene<\/td>\n<td>CR<\/td>\n<td>Normal wear resistance acid salt<\/td>\n<td>&lt;80c<\/td>\n<td>Water<\/td>\n<td>&nbsp;<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td>Polyurethane<\/td>\n<td>PU<\/td>\n<td>Good wear resistance , bad corrosive resistance<\/td>\n<td>&lt;80c<\/td>\n<td>Pulp<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Fluoroplastic<\/td>\n<td>Teflon<\/td>\n<td>PTFE<\/td>\n<td>Acid Salt with stable Chemical properties<\/td>\n<td>&nbsp;<\/p>\n<p>&lt;140c<\/td>\n<td>Acid Salt<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Polyvinyl Fluoride<\/td>\n<td>FEP<\/td>\n<td>Chemical\u00a0 properties same<\/td>\n<td>&lt;180c<\/td>\n<td>Acid Salt<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p align=\"center\"><strong>Flow Meter Installation<\/strong><\/p>\n<p>\u00a0 \u00a0<strong>\u00a01. Installation location<\/strong><\/p>\n<ul>\n<li>Avoid the magnetic objects and equipment with strong electromagnetic field;<\/li>\n<li>should install the flow meter at ventilated location;<\/li>\n<li>Avoid the location wherer ambient temperature above 50\u2103 and relative humidity above 90%;<\/li>\n<li>The water flow meter should be installed at somewhere spacious;<\/li>\n<li>The 4-20Ma Sensor Electromagnetic Water Flow Meter Smart should be installed behind pump and the value should install at downstream.<\/li>\n<\/ul>\n<p align=\"center\"><strong>Flow Sensor Installation<\/strong><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li>Must to ensure the pipeline is filled and without bubbles to keep the high accuracy;<\/li>\n<li>The flow direction should keep with sign on the body of flow meter;<\/li>\n<li>Ensure the double electrodes keep Horizontal;<\/li>\n<li>If the medium is mixed by liquid and solid,Pls install it at vertical to extend the working life of lining;<\/li>\n<li>If the environment with shocked pls install the bracket at both front and behind;<\/li>\n<li>If the medium is pollution liquid, should install the flow meter at bypass pipe and don&#8217;t interrupted when you on service;<\/li>\n<\/ul>\n<p align=\"center\"><strong>TROUBLESHOOTING<\/strong><\/p>\n<p>&nbsp;<\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td><strong>Symptom<\/strong><\/td>\n<td><strong>Probable Cause<\/strong><\/td>\n<td><strong>Solution<\/strong><\/td>\n<td><\/td>\n<td height=\"25\"><\/td>\n<\/tr>\n<tr>\n<td>Measurement is not<\/td>\n<td rowspan=\"3\">1. Parameter wrong<\/td>\n<td rowspan=\"2\">Check the parameters (Transmitter,<\/td>\n<td rowspan=\"2\">\n<p align=\"right\">\n<\/td>\n<td height=\"15\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">accurate<\/td>\n<td height=\"33\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">K factor and size)<\/td>\n<td><\/td>\n<td height=\"10\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td height=\"6\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td height=\"6\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>2. Pipe is not fully filled<\/td>\n<td>Check if meter is fully filled<\/td>\n<td><\/td>\n<td height=\"22\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td colspan=\"2\"><\/td>\n<td height=\"7\"><\/td>\n<\/tr>\n<tr>\n<td>Flow rate indication is<\/td>\n<td><\/td>\n<td colspan=\"2\">(1)\u00a0 Make\u00a0 sure\u00a0 meter\u00a0 is \u00a0properly<\/td>\n<td height=\"15\"><\/td>\n<\/tr>\n<tr>\n<td>unstable<\/td>\n<td><\/td>\n<td>grounded to a good earth ground<\/td>\n<td><\/td>\n<td height=\"15\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>1. Grounding issue<\/td>\n<td colspan=\"2\">(2) Please use ground ring when the pipe<\/td>\n<td height=\"15\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td colspan=\"2\">is not conductive, such as PVC or other<\/td>\n<td height=\"15\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>plastic pipe<\/td>\n<td><\/td>\n<td height=\"16\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td rowspan=\"2\">2. Air<\/td>\n<td>Make\u00a0 sure\u00a0 fluid\u00a0 does\u00a0 not\u00a0 contain<\/td>\n<td>\n<p align=\"right\">air<\/p>\n<\/td>\n<td height=\"17\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td rowspan=\"2\">bubbles<\/td>\n<td><\/td>\n<td height=\"8\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td height=\"8\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td colspan=\"2\"><\/td>\n<td height=\"3\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>3. Converter location \u2013 outside<\/td>\n<td colspan=\"2\">Make sure Converter is not too close to<\/td>\n<td height=\"18\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>electrical interference<\/td>\n<td>sources of electrical interference<\/td>\n<td><\/td>\n<td height=\"15\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td height=\"4\"><\/td>\n<\/tr>\n<tr>\n<td>No Display<\/td>\n<td>1. No power<\/td>\n<td>Apply correct power<\/td>\n<td><\/td>\n<td height=\"18\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td height=\"4\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>2. Incorrect power<\/td>\n<td>Check power value<\/td>\n<td><\/td>\n<td height=\"18\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td colspan=\"2\"><\/td>\n<td height=\"4\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>3. Wiring connections<\/td>\n<td colspan=\"2\">Check power input\/output connections<\/td>\n<td height=\"18\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td height=\"4\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>4. Fuse blown<\/td>\n<td>Replace fuse<\/td>\n<td><\/td>\n<td height=\"18\"><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td height=\"5\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><\/h3>\n<h3><\/h3>\n<h3><strong>Operating conditions<\/strong><\/h3>\n<table border=\"0\" width=\"636\" cellspacing=\"0\" cellpadding=\"0\" align=\"left\">\n<tbody>\n<tr>\n<td><\/td>\n<td><strong>Temperature<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>Process temperature<\/strong><\/td>\n<td><strong>Hard rubber liner: <\/strong><strong>\u2010<\/strong><strong>5&#8230;+60\u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>Polypropylene liner: <\/strong><strong>\u2010<\/strong><strong>5&#8230;+90\u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>PTFE liner: <\/strong><strong>\u2010<\/strong><strong>5&#8230;+120\u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>Ambient temperature<\/strong><\/td>\n<td><strong>Standard (with aluminum converter housing):<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>(all versions)<\/strong><\/td>\n<td><strong>\u2010<\/strong><strong>20\u2026+60\u00b0C (Protect electronics against self<\/strong><strong>\u2010<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>heating with ambient temperatures above 55\u00b0C)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>Storage temperature<\/strong><\/td>\n<td><strong>\u2010<\/strong><strong>20&#8230;+70\u00b0<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>Pressure<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>EN 1092<\/strong><strong>\u2010<\/strong><strong>1<\/strong><\/td>\n<td><strong>DN2200&#8230;3000: PN 2.5<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>DN1200&#8230;2000: PN 6<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>DN200&#8230;1000: PN 10<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>DN65&#8230;150: PN 16<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>DN10&#8230;50 : PN 40<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>Other pressures on request<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>ISO insertion length<\/strong><\/td>\n<td><strong>Optional for DN15&#8230;600<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>ASME B16.5<\/strong><\/td>\n<td><strong>1&#8230;24&#8243;: 150 lb RF<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>Other pressures on request<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>DN10&#8230;1000 \/ 2&#8230;40&#8243;: 10 K<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><strong>Other pressures on request<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>Pressure drop<\/strong><\/td>\n<td><strong>Negligible<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p><strong>Principle of Operation<\/strong><\/p>\n<p>Faraday&#8217;s Law The operation of a magnetic flow meter or mag meter<\/p>\n<p>is based upon Faraday&#8217;s Law, which states that the voltage induced<\/p>\n<p>across any conductor as it moves at right angles through a magnetic<\/p>\n<p>field is proportional to the velocity of that conductor.<\/p>\n<p><strong>Faraday&#8217;s Formula<\/strong><\/p>\n<p>E is proportional to V x B x D where:<\/p>\n<p>E = The voltage generated in a conductor<\/p>\n<p>V = The velocity of the conductor<\/p>\n<p>B = The magnetic field strength<\/p>\n<p>D = The length of the conductor<\/p>\n<p><strong>Application :<\/strong><\/p>\n<p><strong>Juice Milk Mag Flow Meter with pulse;4~20mA and RS485 output<\/strong><\/p>\n<p><strong>Sensor Output:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong><\/p>\n<p>Pulse;4~20mA;HART;RS485;MODBUS;GPRS<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Lining and Body\u00a0 Matereial<\/strong><\/p>\n<p>PTFE, Rubber Lining and cast<\/p>\n<p>steel; stainless steel body material<\/p>\n","protected":false},"featured_media":3168,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[121,64],"product_tag":[],"class_list":["post-1385","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-electromag-flow-meter","product_cat-flow-meter"],"_links":{"self":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product\/1385","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/comments?post=1385"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/media\/3168"}],"wp:attachment":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/media?parent=1385"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1385"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1385"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}