{"id":1369,"date":"2018-04-09T03:11:01","date_gmt":"2018-04-09T03:11:01","guid":{"rendered":"http:\/\/sw-themes.com\/porto_dummy\/product\/import-placeholder-for-1252\/"},"modified":"2022-04-06T10:24:11","modified_gmt":"2022-04-06T10:24:11","slug":"gas-flow-meter-orifice","status":"publish","type":"product","link":"https:\/\/hindelectrical.com\/index.php\/product\/gas-flow-meter-orifice\/","title":{"rendered":"Gas Flow Meter Orifice"},"content":{"rendered":"<h3><strong>Technical Data<\/strong><\/h3>\n<table border=\"0\" width=\"568\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td><strong>Nominal Bore:<\/strong><\/td>\n<td><strong>DN20~\u00a0DN2000mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Nominal Pressure<\/strong><\/td>\n<td><strong>0.6 ~\u00a032MPa(\u226520MPaHigh-pressure\u00a0lens plate\u00a0or fully welding\u00a0)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Medium Temperature<\/strong><\/td>\n<td><strong>-20 ~\u00a0530<\/strong><strong>\u2103<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy<\/strong><\/td>\n<td><strong>\u00b10.5% ~\u00a0\u00b11.5%<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>orifice plate and pressure tapping:<\/strong><\/p>\n<table border=\"0\" width=\"618\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td rowspan=\"2\">&nbsp;<\/p>\n<p><strong>Mode<\/strong><\/td>\n<td rowspan=\"2\">&nbsp;<\/p>\n<p><strong>Nominal Bore<\/strong><\/td>\n<td rowspan=\"2\">&nbsp;<\/p>\n<p><strong>Aperture proportion<br \/>\n\u03b2=d\/D<\/strong><\/td>\n<td rowspan=\"2\">&nbsp;<\/p>\n<p><strong>Renault range<\/strong><\/p>\n<p><strong>Red<\/strong><\/td>\n<td rowspan=\"2\">&nbsp;<\/p>\n<p><strong>Nominal pressure<\/strong><\/p>\n<p><strong>MPa<\/strong><\/td>\n<td colspan=\"3\"><strong>\u00a0 Material<\/strong><\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/p>\n<p><strong>Orifice plate<\/strong><\/td>\n<td>&nbsp;<\/p>\n<p><strong>Ring casing<\/strong><\/td>\n<td>&nbsp;<\/p>\n<p><strong>Flange<\/strong><\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/p>\n<p><strong>Angle joint<\/strong><\/td>\n<td><strong>20~2000<\/strong><\/td>\n<td><strong>0.2~0.75<\/strong><\/td>\n<td><strong>5\u00d710<sup>3<\/sup>~10<sup>8<\/sup><\/strong><\/td>\n<td rowspan=\"2\"><strong>0.6~6.3<\/strong><\/td>\n<td rowspan=\"2\">&nbsp;<\/p>\n<p><strong>Stainless steel<\/strong><\/td>\n<td rowspan=\"2\">&nbsp;<\/p>\n<p><strong>Stainless steel or Carbon steel<\/strong><\/td>\n<td rowspan=\"2\">&nbsp;<\/p>\n<p><strong>Stainless steel or Carbon steel<\/strong><\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/p>\n<p><strong>Flange<\/strong><\/td>\n<td><strong>20~2000<\/strong><\/td>\n<td><strong>0.2~0.75<\/strong><\/td>\n<td><strong>8\u00d710<sup>3<\/sup>~10<sup>8<\/sup><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>The application of the Orifice flow meter<\/strong><\/p>\n<p>It is widely used in petroleum, chemical, metallurgy, power generation and other industrial sectors and municipal construction and environmental Protection projects. Implementation of flow measurement and detection and Control of liquids (such as: water, oil, alcohol and other chemical liquids), gases (Such as: air, oxygen, nitrogen, natural gas, gas and other gases) and steam (Saturated steam, superheated steam).<\/p>\n","protected":false},"excerpt":{"rendered":"<h3><strong>ILUX-OF-1002 GAS FLOW METER ORIFICE<\/strong><\/h3>\n<h3><strong>Working Principle:<\/strong><\/h3>\n<p>The running medium which flow through throttle flow equipment, filled with pipe .And it form local constriction near the throttle flow, the flow speed increase . So it can form the static differential pressure between the upward position and backward position . At the condition of the all known parameters, it can make a deduction of the relation between Differential pressure and flow range according to the theory of continuous flow and Bernoulli Equation, then impetrate the flow range .The fundamental formula is as below :<\/p>\n<div class=\"summary entry-summary col-sm-6\">\n<div>\n<p>C-output\u00a0coefficient\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0dimensionless<\/p>\n<p>d-throttling\u00a0piece\u00a0of\u00a0the\u00a0throttle\u00a0flow\u00a0orifice\u00a0at\u00a0the\u00a0working\u00a0condition\u00a0or\u00a0the\u00a0laryngeal\u00a0diameter<\/p>\n<p>D-upward\u00a0internal\u00a0pipe\u00a0diameter\u00a0at\u00a0the\u00a0working\u00a0condition<\/p>\n<p>qm-mass\u00a0flow\u00a0\u00a0Kg\/s<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<div class=\"summary entry-summary col-sm-12\">\n<p>&nbsp;<\/p>\n<p>qv-volume\u00a0flow\u00a0\u00a0m&amp;sup3;\/s<\/p>\n<p>\u00df-diameter\u00a0rate\u00a0d\/D\u00a0\u00a0\u00a0\u00a0\u00a0dimensionless<\/p>\n<p>The\u00a0density\u00a0of\u00a0the\u00a0running\u00a0medium\u00a0Kg\/m&amp;sup3;<\/p>\n<p>Coefficient\u00a0\u00a0\u00a0dimensionless<\/p>\n<p>The\u00a0structure\u00a0of\u00a0the\u00a0orifice\u00a0flow\u00a0meter:<\/p>\n<p>The\u00a0compose\u00a0of\u00a0the\u00a0throttle\u00a0flow\u00a0equipment<\/p>\n<p>1.\u00a0The\u00a0throttle\u00a0flow\u00a0pieces:\u00a0standard\u00a0orifice\u00a0plate, standard\u00a0nozzle, long\u00a0pathway\u00a0nozzle,<\/p>\n<p>1\/4\u00a0circular\u00a0orifice\u00a0plate, double\u00a0orifice\u00a0plate, eccentric\u00a0orifice\u00a0plate,<\/p>\n<p>Minus\u00a0circle\u00a0orifice\u00a0plate,<\/p>\n<p>taper\u00a0entrance\u00a0orifice\u00a0plate\u00a0etc\u00a0.<\/p>\n<p>2\u00a0.fetching\u00a0pressure\u00a0equipment: loop\u00a0chamber, fetching\u00a0pressure\u00a0flange, holding\u00a0collar,<\/p>\n<p>Connecting\u00a0pipe\u00a0etc\u00a0.<\/p>\n<p>3\u00a0.flange\u00a0connection\u00a0\u00a0(\u00a0country\u00a0standard\u00a0,different\u00a0kinds\u00a0of\u00a0standard\u00a0and\u00a0other<\/p>\n<p>Designed\u00a0department\u2019s\u00a0\u00a0flange\u00a0)\u00a0,fastener\u00a0.<\/p>\n<p>4\u00a0.measuring\u00a0tube<\/p>\n<p><strong>Description:<\/strong><\/p>\n<p>The orifice flow meter which consist of the standard orifice and multi-Parameters differential pressure transducer and temperature transducer .The Differential pressure equipment with high measurement range rate .It can Measure the flux of the gas ,steam, liquid and the natural gas in the \u00a0Chemical Plant, Power Plant, Steel Industry and water supply etc.<\/p>\n<p><strong>Application range orifice flow meter<\/strong><\/p>\n<p>1.Diameter : 15 mm \u2264DN\u22641200mm<\/p>\n<p>2.Pressure : PN\u226410MPa<\/p>\n<p>3.Working temperature :\u00a0-50\u2103\u2264t\u2264550\u2103<\/p>\n<p>4.Measurment range rate : 1:10,\u00a01:15<\/p>\n<p>5.Accuracy :0.5 % ,1%<\/p>\n<p><strong>Orifice<\/strong><strong>\u00a0Flow Meter<\/strong><strong>\u00a0 Features:<\/strong><\/p>\n<ul>\n<li><strong>The orifice flow meter usage in \u00a0Steam , Gas and Water to calculate all the signal-phase flow and it can also measure part of mix-phase flow .<\/strong><strong>It is the standard throttle flow equipment which can use without actual flow to calibration .<\/strong><\/li>\n<li><strong>The integrated type is easy to installation, it can directly connect the differential pressure transducer and pressure transducer .<\/strong><\/li>\n<li><strong>High accuracy, perfect self-diagnose function.<\/strong><\/li>\n<li><strong>It can self-adjust the range of the orifice flow meter through programming<\/strong><\/li>\n<li><strong>It can display total flow, instantaneous flow, pressure and temperature at the same time .<\/strong><\/li>\n<li><strong>Matched manifold communication interface.<\/strong><\/li>\n<li><strong>High stability .<\/strong><\/li>\n<li><strong>Wide measurement range ,over 10:1.<\/strong><\/li>\n<li><strong>\u00a0High accuracy :+\/-0.075%<\/strong><\/li>\n<li><strong>High stable capability : excel 0.1%<\/strong><\/li>\n<li><strong>High static pressure : 40MPa<\/strong><\/li>\n<li><strong>It can ignore the effect of the temperature and the static pressure.<\/strong><\/li>\n<\/ul>\n<\/div>\n","protected":false},"featured_media":3216,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[64,123],"product_tag":[],"class_list":["post-1369","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-flow-meter","product_cat-orifice-flow-meter"],"_links":{"self":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product\/1369","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/comments?post=1369"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/media\/3216"}],"wp:attachment":[{"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/media?parent=1369"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1369"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/hindelectrical.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1369"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}